HPI-DT series 5~315KVA

► ULTRA WIDE INPUT VOLTAGE RANGE

    115V to 280V Ultra Wide input voltage range design. IVR can work in normal even

    at the worst input voltage range. All components have been strictly selected which are

    able to resist transient surge & huge current.

► PRECISE & LINEAR VOLTAGE REGULATION

    Adopt electromagnetic induction working principle to do linear voltage regulation.

    No contact movement; no noise coupling; no boost or sag, to ensure power quality

    of load remains the same as the input.

► STURDY, DURABLE, LONG LIFE SPAN

    No Sliding Contacts. Brush-less. No Sparks. No Components to wear out. Capable to

    sustain spikes & non-linear load anti-electric feedback. High Reliability and Long Life Span.

► ADVANCED FULL PROTECTION WITH BUZZER ALARM & INDICATORS FLASHING

    When output voltage is out of range, overload, short circuit, phase failure, phase reversed,

    over temperature or abnormal control circuit, the output will be cut off automatically,

    buzzer alarms and LED indicators is flashing.

► SURGE AND LIGHTNING PROTECTION

    Surge suppressor and / or Lightning Arrestor are built-in. Capable to absorb transient

    surge voltage from power grids.

► HARSH ENVIRONMENT DESIGN

    Composed of high efficiency and wide safety range of industrial grade components,

    the IVR can sustain severe temperature, humidity, vibration and dirty environments.

► SOFT START WHILE AUTO RESTORE FROM AC POWER RECOVERY

    Instantaneous power blackouts and restore will damage electrical loads. While AC power

    recovery, the IVR starts automatically from low voltage output, to ensure the security of load.

► STRONG OVERLOAD CAPABILITY

    The IVR will not be damaged when short circuit happened on the loads or over current in

    transient. 150% / 90seconds, 200% / 20seconds, 300% /10seconds.

► LOW POWER LOSS.  HIGH EFFICIENCY

    Low Iron loss silicon steel sheets, oxygen-free enameled wires, they help the voltage

    regulators develop high performance, less power loss.

► SELF-DETECT REGULATOR SYSTEM

    When the internal voltage regulating circuit doesn’t work, the IVR will have self-testing.

► MASTER CIRCUIT & SLAVE CIRCUIT INTERLOCKED PROTECTION

    The IVR have circuit interlocked protection of voltage regulating circuitry and monitoring

    control circuitry.

 ► FAST RESPONSE TIME

     < 50 millisecond

► AUTOMATIC BYPASS OUTPUT

    The IVR with Automatic Bypass function.  When the output voltage is abnormal, when the

    input voltage is within the setting range, the IVR will switch automatically to bypass, no

    manpower to operate.

► PASSWORD TO OPEN THE DOOR FUNCTION

    The IVR requires a password to open the door locks, no key, just enter your password on

    the touch screen and open the front door of the IVR.

► FULLY ISOLATED MANUAL BYPASS

    When the IVR is failed or required maintenance in Bypass mode, it can changeover the

    Double Throw Bypass Switch manually to mains through the load. The IVR remains

    overload and short circuit protection in Bypass mode. To ensure the IVR stability, voltage

    regulator circuit and protection circuit are detected by use an independent power supply

    in order to avoid electrical fault, causing malfunction.

► LCD TOUCH PANEL DISPLAY

    Intuitive Touch Panel to show system descriptions, System Status, loading Status,

    System Settings, Event Logs. Option: Big LCD display to show input voltage, output voltage,

    output current and IVR status.

► RS485 COMMUNICATION INTERFACE FUNCTION

    The IVR with RS-485 communication interface, via MODBUS communication protocol, users

    can design their own software, monitor the parameters of AVS through the computer at any

    time.

► HISTORY EVENTS FEATURE

    The IVR with History Events function, you can always check the IVR of the history of

    working time, including System On/Off, Abnormal Conditions, Bypass / Voltage Regulation,

    Open / Close the front door and so on.

► EXTERNAL DRY CONTACTS FOR ABNORMAL SIGNAL

    The front panel of IVR provides all kinds of abnormal signals (DC5V) for external control.

► MULTI-LAYER TYPE CIRCUITRY CONTROL

    To ensure its reliability, all separate PCBs (voltage regulation, protection, monitoring & control,

    drive circuit board) are isolated from each other.

► CPU CONTROLLED

► CUSTOM-MADE WELCOME

    Listen and design to meet with your demands.

 

Use of Data
We use cookies to process data, such as your IP address, for content personalization, advertising, and analytics.Usage data may be shared with our partners and combined with other information.
By using this site, you agree. Taiwantrade & iDealEZ’s Privacy Policy

Welcome to Taiwantrade.com

Taiwantrade.com and iDealEZ.com uses analytical cookies and other tracking technologies to offer you the best possible user experience. By using our website, you acknowledge and agree to our cookie policy.

For more information on cookies or changing your cookies settings, read Taiwantrade & iDealEZ’s Privacy Policy.